AFE200 • Instruction Manual 97
10 - ANALOG OUTPUTS
On the AFE200 regulation card there are two programmable analog outputs.
Analog output 1 supplies a two-pole +/-10VDC voltage signal, while analog output 2 can be program-
med to obtain a 0-20mA or 4-20mA output signal in current or a signal in two-pole +/-10VDC voltage,
depending on the parameter assigned.
Table: value of the signal of the analog outputs according to the measurement used
PAR Description Full scale output
250 Output current
10V = 200% Heavy Duty drive rated current (this value can be found
in the manual and is defined @400Vac, default switching frequency
and 40°C)
280 Active current ref
282 React curr ref mon
284 Active current
286 Reactive current
2388 Active curr noflt
252 Output voltage 10V = 200% Mains voltage (PAR 560)
254 Output frequency 10V = 1000Hz
270 DC link voltage 10V = 7000V