AGL50-EV 37
d.220 Reserved 032
d.221 Reserved 033
d.222 Reserved 034
d.250 LCW To PLC (0-7) Monitor of the control bits sent to the internal sequencer. Bit 0 to 7 66
d.251 LCW To PLC(8-15) Monitor of the control bits sent to the internal sequencer. Bit 8 to 15 67
d.252 LCW Fr PLC (0-7) Monitor of the control bits generated by the internal sequencer. Bit 0 to 7 68
d.253 LCW Fr PLC(8-15) Monitor of the control bits generated by the internal sequencer. Bit 8 to 15 69
d.254 LCW FrPLC(16-23) Monitor of the control bits generated by the internal sequencer. Bit 16 to 23 70
d.255 LSW (0-7) Monitor of the drive status. Bit 0 to 7. 71
d.300 EncPulses/Sample Number of encoder pulses, 1/100 035
recorded in the time interval dened by parameter I.504.
d.301 Encoder freq Encoder frequency reading (Motor frequency) Hz 0.01 036
d.302 Encoder speed Encoder speed reading (d.000)*(P.600) 0.01/1 037
d.350 Reserved
d.351 Reserved
d.353 Reserved
d.354 Reserved
d.400 PID reference PID reference signal % 0.1 041
d.401 PID feedback PID feedback signal % 0.1 042
d.402 PID error PID error signal % 0.1 043
d.403 PID integr comp PID integral component % 0.1 044
d.404 PID output PID output signal % 0.1 045
d.450 Mdplc error Status of internal sequencer 62
0 No error
1 Internal sequencer error
d.500 Lift space m 0.01 63
Space needed to accelerate the car from zero to max speed and then decelerate back to zero
d.501 Lift space
Space needed to accelerate the car from zero to max speed
d.502 Lift space m 0.01 65
Space needed to decelerate the car from max speed to zero
d.800 1st alarm-latest Last alarm stored by the drive alarm list 046
See par. 10.3
d.801 2nd alarm Second to last alarm 047
d.802 3rd alarm Third to last alarm 048
d.803 4th alarm Fourth to last alarm 049
d.950 Drive rated curr Drive rated current (it depends on the drive size) 0.1 050
d.951 SW version (1/2) Software version - part 1 (03.01) 0.01 051
d.952 SW version (2/2) Software version - part 2 (00.00) 0.01 052
d.957 Drive size Drive size code 057
7 4kW - 400/460V
8 5.5kW - 400/460V
9 7.5kW - 400/460V
d.958 Drive cfg type Drive conguration type 061
[0]Standard: 400Vac, 50Hz
[1] American: 460Vac, 60Hz
d.999 Display Test Drive display test