42 AGL50-EV
9 - Parameter list
Figure 9.1: Parameters Description Legend
Code
(A)
PARAMETER PICK LIST
Def.
(D)
Min
(E)
Max
(F)
Unit
(G)
Variat.
(H)
IPA
(I)
Name
(B)
DESCRIPTION Selection
(C)
Description
START-UP
S.000 Mains voltage Rated value of the line voltage 230 400 230 480 V
404
(P.020)
380
400
420
440
460
480
S.001 Mains frequency Rated value of the line frequency 50 50 50 60 Hz
405
(P.021)
60
(A) CODE: Parameter Code, showed on display.
Format=X.YYY:
X=Menu d=DISPLAY S=STARTUP I=INTERFACE F=FREQ & RAMPS
P=PARAMETER A=APPLICATION C=COMMAND H=HIDDEN
YYY = Parameter number
(B) Parameter name
(C) Selection list, code [IN BRAKET]
(D) Parameter default value
(E) Parameter minimum value
(F) Parameter maximum value
G) Parameter unit of measure
(H) Parameter step of variation
(I) Parameter sw number, used via serial
If IPA bold= not writable parameter with running motor
Note!
(ALIAS): On STARTUP menu only.
Parameter code of same parameter on other menu .
(*): Parameter value depends on the drive size.