AGL50-EV 43
Code
PARAMETER PICK LIST
Def. Min Max Unit Variat. IPA
Name DESCRIPTION Selection Description
DISPLAY
d.000 Output frequency Drive output frequency Hz 0.01 001
d.001 Frequency ref Drive frequency reference Hz 0.01 002
d.002 Output current Drive output current (rms) A 0.1 003
d.003 Output voltage Drive output voltage (rms) V 1 004
d.004 DC link voltage DC Bus drive voltage (DC) V 1 005
d.005 Power factor Power factor 0.01 006
d.006 Power [kW] Inverter output power kW 0.01 007
d.007 Output speed Drive output speed mm/s 1 008
d.008 Speed ref Drive speed reference (d.001)*(P.600) mm/s 1 009
d.050 Heatsink temp
Drive heatsink temperature (linear sensor
measured)
°C 1 010
d.051 Drive OL Drive overload (100% = alarm threshold) % 0.1 011
d.052 Motor OL Motor overload (100% = alarm threshold) % 0.1 012
d.053 Brake res OL
Braking resistor overload (100%=alarm
thr)
% 0.1 013
d.100 Dig inp status
Digital inputs status acquired by the drive
(terminal or virtual)
014
d.101 Term inp status
Digital inputs terminal status of the drive
regulat. Board
015
d.102 Vir dig inp stat
Virtual digital inputs status from drive
serial link
016
d.120 Exp dig inp stat
Expansion digital inputs status (optional
terminal or virtual)
017
d.121 Exp term inp
Expansion digital inputs terminal status of
the drive expansion board
018
d.122 Vir exp dig inp
Expansion virtual digital inputs status from
drive serial link
019
d.150 Dig out status
Digital outputs status on the terminals of
the drive regulation board (commanded by
DO functions or virtual DO)
020
d.151 Drv dig out sta
Digital outputs status, commanded by DO
functions
021
d.152 Vir dig out sta
Virtual digital outputs status, commanded
via serial link
022
d.170 Exp dig out sta
Expansion digital outputs status on the
terminals of the drive regulation board
(commanded by DO functions or virtual
DO)
023
d.171 Exp DrvDigOutSta
Expansion digital outputs status, com-
manded by DO functions
024
d.172 Exp VirDigOutSta
Expansion virtual digital outputs status,
commanded via serial link
025
d.200 An in 1 cnf mon
Analog input 1 destination; it shows the
function associated to this analog input
[0] Null funct 026
[1] Freq ref 1
[2] Freq ref 2
[3] Bst lev fact
[4] OT lev fact
[5] Vred lev fac
[6] DCB lev fact
[7] RampExt fact
[8] Freq Ref fact
[9] SpdPI LimFac
[10] MltFrq ch 1
[11] MltFrq ch 2
d.201 An in 1 monitor Analog input 1 output block % value 027
d.202 An in 1 term mon Analog input 1 input block % value 028

Related product manuals