EasyManua.ls Logo

gefran AGL50-EV Series

gefran AGL50-EV Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44 AGL50-EV
Code
PARAMETER PICK LIST
Def. Min Max Unit Variat. IPA
Name DESCRIPTION Selection Description
d.210 Reserved
d.211 Reserved
d.212 Reserved
d.220 Reserved
d.221 Reserved
d.222 Reserved
d.250 LCW To PLC (0-7)
Monitor of the control bits sent to the
internal sequencer. Bit 0 to 7
66
d.251 LCW To PLC(8-15)
Monitor of the control bits sent to the
internal sequencer. Bit 8 to 15
67
d.252 LCW Fr PLC (0-7)
Monitor of the control bits generated by the
internal sequencer. Bit 0 to 7
68
d.253 LCW Fr PLC(8-15)
Monitor of the control bits generated by the
internal sequencer. Bit 8 to 15
69
d.254 LCW FrPLC(16-24)
Monitor of the control bits generated by the
internal sequencer. Bit 16 to 24
70
d.255 LSW (0-7) Monitor of the drive status. Bit 0 to 7 71
d.300 EncPulses/Sample
Number of encoder pulses, recorded in the
time interval dened by parameter I.504.
1/100 035
d.301 Encoder freq
Encoder frequency reading (Motor
frequency)
Hz 0.01 036
d.302 Encoder speed Encoder speed reading (d.000)*(P.600) 0.01/1 037
d.350 Reserved
d.351 Reserved
d.353 Reserved
d.354 Reserved
d.400 PID reference PID reference signal % 0.1 041
d.401 PID feedback PID feedback signal % 0.1 042
d.402 PID error PID error signal % 0.1 043
d.403 PID integr comp PID integral component % 0.1 044
d.404 PID output PID output signal % 0.1 045
d.450 Mdplc error Status of internal sequencer 0 No error
1 Internal sequencer error 62
d.500 Lift space
Space needed to accelerate the car from
zero to max speed and then decelerate
back to zero
m 0.01 63
d.501 Lift accel space
Space needed to accelerate the car from
zero to max speed
m 0.01 64
d.502 Lift decel space
Space needed to decelerate the car from
max speed to zero
m 0.01 65
d.800 1st alarm-latest Last alarm stored by the drive alarm list See paragraph 9.3 046
d.801 2nd alarm Second to last alarm 047
d.802 3rd alarm Third to last alarm 048
d.803 4th alarm Fourth to last alarm 049
d.950 Drive rated curr
Drive rated current (it depends on the
drive size)
0.1 050
d.951 SW version (1/2) Software version - part 1 03.01 0.01 051
d.952 SW version (2/2) Software version - part 2 00.00 0.01 052
d.957 Drive size Drive size code 057
4 4kW - 230/400/460V
5 5.5kW - 230/400/460V
6 7.5kW - 230/400/460V
d.958 Drive cfg type Drive conguration type
[0]Standard:400
[1]American:460
Standard: 400Vac, 50Hz
American: 460Vac, 60Hz
061
d.999 Display Test Drive display test 099

Related product manuals