AGL50-EV 45
Code
PARAMETER PICK LIST
Def. Min Max Unit Variat. IPA
Name DESCRIPTION Selection Description
START-UP
S.000 Mains voltage Rated value of the line voltage 230 400 230 480 V
404
(P.020)
380
400
420
440
460
480
S.001 Mains frequency Rated value of the line frequency 50 50 50 60 Hz
405
(P.021)
60
S.100 Base voltage Motor base (rated) voltage 380 50 528 V 1
413
(P.061)
S.101 Base frequency Rated frequency of the motor 50 25 250 Hz 0.1
414
(P.062)
S.150 Motor rated curr Rated current of the motor (*) (*) (*) A 0.1
406
(P.040)
S.151 Motor pole pairs Pole Pairs of the motor 2 1 60 0.01
407
(P.041)
S.152 Motor power fact Motor power factor (*) 0.01 1 0.01
408
(P.042)
S.153 Motor stator R
Measurement of the stator resistance of
the motor
(*) 0 99.99 ohm
409
(P.043)
S.170 Measure stator R Motor Autotune command Off (1) (1) (2)
806
(C.100)
do
S.180 Car max speed
Speed of the lift car when the inverter
output frequency is equal to S.101
0.50 0.01 5.00 m/s 0.01
1323
(A.090)
S.200 Frequency ref 0 Digital reference frequency 0 10.0 -F.020 F.020
311
(F.100)
S.201 Frequency ref 1 Digital reference frequency 1 50.0 -F.020 F.020
312
(F.101)
S.202 Frequency ref 2 Digital reference frequency 2 0 -F.020 F.020
313
(F.102)
S.203 Frequency ref 3 Digital reference frequency 3 0 -F.020 F.020
314
(F.103)
S.204 Frequency ref 4 Digital reference frequency 4 0 -F.020 F.020
315
(F.104)
S.205 Frequency ref 5 Digital reference frequency 5 0 -F.020 F.020
316
(F.105)
S.206 Frequency ref 6 Digital reference frequency 6 0 -F.020 F.020
317
(F.106)
S.207 Frequency ref 7 Digital reference frequency 7 0 -F.020 F.020
318
(F.107)
S.220 Smooth start frq Frequency reference during smooth start 2.0 -F.020 F.020
327
(F.116)
S.225 Ramp factor 1
Multiplier for acc/dec and jerks of ramp
sets 1 and 3
1.00 0.01 2.50 0.01
1324
(A.091)
S.226 Ramp factor 2
Multiplier for acc/dec and jerks of ramp
sets 2 and 4
1.00 0.01 2.50 0.01
1327
(A.092)
S.230 Jerk acc ini 1
Jerk applied at the beginning of an accele-
ration with ramp set 1
0.50 0.01 10.00 m/s3 0.01
343
(F.251)
S.231 Acceleration 1 Linear acceleration with ramp set 1 0.60 0.01 5.00 m/s2 0.01
329
(F.201)
S.232 Jerk acc end 1
Jerk applied at the end of an acceleration
with ramp set 1
1.40 0.01 10.00 m/s3 0.01
344
(F.252)
S.233 Jerk dec ini 1
Jerk applied at the beginning of a decele-
ration with ramp set 1
1.40 0.01 10.00 m/s3 0.01
345
(F.253)