46 AGL50-EV
Code
PARAMETER PICK LIST
Def. Min Max Unit Variat. IPA
Name DESCRIPTION Selection Description
S.234 Deceleration 1 Linear deceleration with ramp set 1 0.60 0.01 5.00 m/s2 0.01
330
(F.202)
S.235 Jerk dec end 1
Jerk applied at the end of a deceleration
with ramp set 1
1.00 0.01 10.00 m/s3 0.01
346
(F.254)
S.240 Jerk acc ini 2
Jerk applied at the beginning of an accele-
ration with ramp set 2
1.00 0.01 10.00 m/s3 0.01
347
(F.255)
S.241 Acceleration 2 Linear acceleration with ramp set 2 0.60 0.01 5.00 m/s2 0.01
331
(F.203)
S.242 Jerk acc end 2
Jerk applied at the end of an acceleration
with ramp set 2
1.40 0.01 10.00 m/s3 0.01
348
(F.256)
S.243 Jerk dec ini 2
Jerk applied at the beginning of a decele-
ration with ramp set 2
1.40 0.01 10.00 m/s3 0.01
349
(F.257)
S.244 Deceleration 2 Linear deceleration with ramp set 2 0.60 0.01 5.00 m/s2 0.01
332
(F.204)
S.245 Jerk dec end 2
Jerk applied at the end of a deceleration
with ramp set 2
1.00 0.01 10.00 m/s3 0.01
350
(F.258)
S.250 Cont close delay RUN contactor close delay 0.20 0 10 s 0.01
1316
(A.080)
S.251 Magnet time Motor magnetization time 1 0 10 s 0.01
1317
(A.081)
S.252 Brake open delay Brake contactor open delay 0.20 0 10 s 0.01
1318
(A.082)
S.253 Smooth start dly Smooth start duration 0 0 10 s 0.01
1319
(A.083)
S.254 DCBrake stp time Duration of 0Hz braking at stop 1 0 10 s 0.01
1320
(A.084)
S.255 Brake close dly Brake contactor close delay 0.20 0 10 s 0.01
1321
(A.085)
S.256 Cont open delay RUN contactor open delay 0.20 0 10 s 0.01
1322
(A.086)
S.260 Lift stop mode Lift behavior at stop [0] Dcb at stop
DC brake is perfor-
med after the output
frequency is below P.440
threshold
1 0 1
1350
(A.220)
[1] Normal stop
DC brake is not perfor-
med at stop
S.300 Manual boost [%] Manual boost at low revolutions 3.0 0.0 25.0
% of
S.100
0.1
421
(P.120)
S.301 Auto boost en Automatic boost function enabling [0] Disable 0 0 1
423
(P.122)
[1] Enable
S.310 Slip compensat
Amount of slip compensation during
motoring
50 0 250
% of
rated
slip
1
419
(P.100)
S.311 Slip comp regen
Amount of slip compensation during
regeneration
50 0 250
% of
rated
slip
1
500
(P.102)
S.312 Slip comp lter Time constant of slip compensation 0.3 0 10 s 0.1
420
(P.101)
S.320 DC braking level
Current level used during DC brake at start
and stop
75 0 100
% of
d.950
1
449
(P.300)
S.400 Control mode Drive control mode [0] V/f OpenLoop
Speed control without
encoder feedback
0 0 1
498
(P.010)
[1] V/f ClsdLoop
Speed control with
encoder feedback
S.401 Encoder ppr Pulses per revolution of the encoder in use 1024 1 9999 1
151
(I.501)
S.450 Spd ctrl P-gainL Speed loop Proportional gain 2.0 0 100 % 0.1
503
(P.172)
S.451 Spd ctrl I-gainL Speed loop Integral gain 1.0 0 100 % 0.1
504
(P.173)
S.452 Spd PI High lim Speed PI regulator output upper limit 10 0 100
% of
F.020
0.1
509
(P.176)