EasyManua.ls Logo

gefran AGL50-EV Series

gefran AGL50-EV Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AGL50-EV 47
Code
PARAMETER PICK LIST
Def. Min Max Unit Variat. IPA
Name DESCRIPTION Selection Description
S.453 Spd PI Low lim Speed PI regulator output lower limit -10 -100 0
% of
F.020
0.1
510
(P.177)
S.901 Save parameters Save parameters off” off” off” (“do”)
800
(C.000)
do
INTERFACE
I.000 Enable src
Source of the Enable command of Lift
Control Word
[0] False
The command is never
active
2 0 27 100
[1] True
The command is always
active
[2] DI 1
The command comes
from DigInp1
[3] DI 2
The command comes
from DigInp2
[4] DI 3
The command comes
from DigInp3
[5] DI 4
The command comes
from DigInp4
[6] DI 5
The command comes
from DigInp5
[7] DI 6
The command comes
from DigInp6
[8] DI 7
The command comes
from DigInp7
[9] DI 8
The command comes
from DigInp8
[10] DI Exp 1
The command comes
from ExpDI 1
[11] DI Exp 2
The command comes
from ExpDI 2
[12] DI Exp 3
The command comes
from ExpDI 3
[13] DI Exp 4
The command comes
from ExpDI 4
[14] AND 1
The command comes
from the output of the
block AND1
[15] AND 2
The command comes
from the output of the
block AND2
[16] AND 3
The command comes
from the output of the
block AND3
[17] OR 1
The command comes
from the output of the
block OR1
[18] OR 2
The command comes
from the output of the
block OR2
[19] OR 3
The command comes
from the output of the
block OR3
[20] NOT 1
The command comes
from the output of the
block NOT1
[21] NOT 2
The command comes
from the output of the
block NOT2
[22] NOT 3
The command comes
from the output of the
block NOT3
[23] NOT 4
The command comes
from the output of the
block NOT4

Related product manuals