48 AGL50-EV
Code
PARAMETER PICK LIST
Def. Min Max Unit Variat. IPA
Name DESCRIPTION Selection Description
[24] FrqSel match
The command is coming
from the output of the
block Freq Sel match
[25] ShortFloorFl
The command is the
short oor ag
[26] Contactor
(fw 03-07)
Active when the RUN
contactor has to be
closed, either for upward
or downward motion
[27] Timer 1
(fw 03-07)
Output of Timer 1
I.001 Run Fwd src
Source of the Run Forward command of
LCW
As for I.000 3 0 27 101
I.002 Run Rev src
Source of the Run Reverse command of
LCW
As for I.000 4 0 27 102
I.003 Freq Sel 1 src
Source of the Frequency Selector 1 of
LCW
As for I.000 5 0 27 103
I.004 Freq Sel 2 src
Source of the Frequency Selector 2 of
LCW
As for I.000 6 0 27 104
I.005 Freq Sel 3 src
Source of the Frequency Selector 3 of
LCW
As for I.000 7 0 27 105
I.006 Freq Sel 4 src
Source of the Frequency Selector 4 of
LCW
As for I.000 0 0 27 106
I.007 Ramp Sel 1 src Source of the Ramp Selector 1 of LCW As for I.000 25 0 27 107
I.008 Ramp Sel 2 src Source of the Ramp Selector 1 of LCW As for I.000 0 0 27 108
I.009 Ext fault src
Source of the External Fault command
of LCW
As for I.000 8 0 27 109
I.010 Faul reset src
Source of the Fault Reset command of
LCW
As for I.000 9 0 27 110
I.011 Bak pwr act src
Source of the Backup Power Supply Active
command of LCW
As for I.000 0 0 27 111
I.012 Forced stop src
Source of the Forced Stop command of
LCW
0 0 27 185
I.100 Dig output 1 cfg Digital output 1 conguration [0] Drive Ready 51 0 78 112
[1] Alarm state
[2] Not in alarm
[3] Motor run
[4] Motor stop
[5] REV rotation
[6] Steady state
[7] Ramping
[8] UV running
[9] Out trq>thr
[10] Current lim
[11] DC-link lim
[12] Limit active
[13] Autocapt run
[14] BU overload
[15] Neg pwrfact
[16] PID err ><
[17] PID err>thr
[18] PID err<thr
[19] PIDer><(inh)
[20] PIDerr>(inh)
[21] PIDerr<(inh)
[22] FWD enc rot
[23] REV enc rot
[24] Encoder stop