AGL50-EV 49
Code
PARAMETER PICK LIST
Def. Min Max Unit Variat. IPA
Name DESCRIPTION Selection Description
[25] Encoder run
[26] Extern fault
[27] No ext fault
[28] Serial TO
[29] freq=thr1
[30] freq!=thr1
[31] freq>thr1
[32] freq<thr1
[33] freq=thr2
[34] freq!=thr2
[35] freq>thr2
[36] freq<thr2
[37] HS temp=thr
[38] HS temp!=thr
[39] HS temp>thr
[40] HS temp<thr
[41] Output freq
[42] Out freq x 2
[43] CoastThrough
[44] EmgStop
[45] DC braking
[46] Drv OL status
[47] Drv OL warn
[48] Mot OL status
[49] Reserved
[50] Reserved
[51] Contactor
Active when the RUN
contactor has to be
closed, either for upward
or downward motion
[52] Contactor UP
Active when the RUN
contactor has to be clo-
sed for upward motion
[53] Contactor DW
Active when the RUN
contactor has to be
closed for downward
motion
[54] Brake cont
Active when the mecha-
nical brake has to be
released
[55] Lift start
Active when the inverter
output bridge is enabled
and DC brake is not in
progress
[56...77] Reserved
[78] Timer 1 out
(fw 03-07)
Output of Timer 1
I.101 Dig output 2 cfg Digital output 2 conguration As for I.100 54 0 78 113
I.102 Dig output 3 cfg Digital output 3 conguration As for I.100 2 0 78 114
I.103 Reserved
I.150 Exp DigOut 1 cfg Extended digital output 1 conguration As for I.100 52 0 78 116
I.151 Exp DigOut 2 cfg Extended digital output 2 conguration As for I.100 53 0 78 117
I.152 Exp DigOut 3 cfg Extended digital output 3 conguration As for I.100 0 0 78 180
I.200 An in 1 Type
Setting of the Analog Input 1 type referen-
ce (voltage)
[0] +/- 10V
Bipolar ± 10V
Unipolar +10V
1 0 1 118
[1] 0-10V/0-20mA
I.201 An in 1 offset Analog Input 1 offset 0 -99.9 99.9 % 0.1 119