232 AGy -L
LCD Display DESCRIPTION LCD Selection Description
Def.
Min
Max
Unit
Variat.
IPA
PARAMETER PICK LIST
Code
I.772 Drv to SBI W 2 Word 2 from drive to SBI
3 0 1999 175
I.773 Drv to SBI W 3 Word 3 from drive to SBI
4 0 1999 176
I.774 Drv to SBI W 4 Word 4 from drive to SBI
5 0 1999 177
I.775 Drv to SBI W 5 Word 5 from drive to SBI
6 0 1999 178
F.000 Motorpot ref Motopot reference (it can be set using up and down
commands)
0 0 F.020 Hz 0.01 300
F.010 Mp Acc/Dec time Motorpot Accel. and Decel. ramp time
10 0.1 999.9 sec 0.1 301
F.011 Motorpot offset Motopotentiometer minimum reference
0 0 F.020 Hz 0.1 302
F.012 Mp output mode Unipolar / bipolar Motorpotentiometer
[0] Unipolar 0 0 1 303
[1] Bipolar
F.013 Mp auto save Motopotenziometer auto save function
[0] Disable 1 0 1 304
[1] Enable
F.014 MpRef at stop
[0] Last value Mot. reference will retain its
current value
0 0 1 351
[1] Follow ramp Mot. reference will ramp down to
zero, following the deceleration
ramp in use
F.020 Max ref freq Motor maximum frequency value (for both directions)
50 25 250 Hz 0.1 305
F.021 Min ref freq Minimum frequency value
0 0 F.020 Hz 0.1 306
F.050 Ref 1 channel Source of the Reference 1
[0] Null Null 4 4 4 307
[1] Analog inp 1 Analog input 1
[2] Analog inp 2 Analog input 2
[3] Freq ref x Frequency reference F.100
(S.203)
[4] Multispeed Multi frequncies
[5] Motorpotent Motorpotientometer reference
[6] Analog inp 3 Analog input 3
[7] Encoder Encoder signal
[8] Profidrive Reference by Profibus
F.051 Ref 2 channel Source of the Reference 2
[0] Null Null 0 0 8 308
[1] Analog inp 1 Analog input 1
[2] Analog inp 2 Analog input 2
[3] Freq ref x Frequency reference F.101
[4] Multispeed Multispeed
[5] Motorpotent Motorpotientometer reference
[6] Analog inp 3 Analog input 3
[7] Encoder Encoder signal
[8] Profidrive Reference by Profibus
F.060 MltFrq channel 1 Source of the Multispeed 1
As for F.050, Reference 1 source 3 0 8 309
F.061 MltFrq channel 2 Source of the Multispeed 2
As for F.051, Reference 2 source 3 0 8 310
F.080 FreqRef fac src Frequency reference multiplier factor source
[0] Null Null 0 0 3 342
[1] Analog inp 1 Analog input 1
[2] Analog inp 2 Analog input 2
[3] Analog inp 3 Analog input 2
F.100 Frequency ref 0 Digital Reference frequency 0
10 -F.020 F.020 Hz 0.1 311
F.101 Frequency ref 1 Digital Reference frequency 1
50 -F.020 F.020 Hz 0.1 312
F.102 Frequency ref 2 Digital Reference frequency 2
0 -F.020 F.020 Hz 0.1 313
F.103 Frequency ref 3 Digital Reference frequency 3
0 -F.020 F.020 Hz 0.1 314
F.104 Frequency ref 4 Digital Reference frequency 4
0 -F.020 F.020 Hz 0.1 315
F.105 Frequency ref 5 Digital Reference frequency 5
0 -F.020 F.020 Hz 0.1 316
F.106 Frequency ref 6 Digital Reference frequency 6
0 -F.020 F.020 Hz 0.1 317
F.107 Frequency ref 7 Digital Reference frequency 7
0 -F.020 F.020 Hz 0.1 318
F.108 Frequency ref 8 Digital Reference frequency 8
0 -F.020 F.020 Hz 0.1 319
F.109 Frequency ref 9 Digital Reference frequency 9
0 -F.020 F.020 Hz 0.1 320
F.110 Frequency ref 10 Digital Reference frequency 10
0 -F.020 F.020 Hz 0.1 321
F.111 Frequency ref 11 Digital Reference frequency 11
0 -F.020 F.020 Hz 0.1 322
F.112 Frequency ref 12 Digital Reference frequency 12
0 -F.020 F.020 Hz 0.1 323
F.113 Frequency ref 13 Digital Reference frequency 13
0 -F.020 F.020 Hz 0.1 324
F.114 Frequency ref 14 Digital Reference frequency 14
0 -F.020 F.020 Hz 0.1 325
F.115 BakPwr max freq Digital refer frequency 15. When in backup power mode, it
defines the upper limit of the inverter output frequency
5 -F.020 F.020 Hz 0.1 326
F.116 Smooth start frq Frequency reference during smooth start
2 -F.020 F.020 Hz 0.1 327
F.201 Acceleration 1 Linear acceleration with ramp set 1
0.6 0.01 5.0
m/s
2
0.01 329
F.202 Deceleration 1 Linear deceleration with ramp set 1
0.6 0.01 5.0
m/s
2
0.01 330
FREQ & RAMP
Behavior of the frequency reference from Motorpotentiometer
during a Stop sequence