English
AGy -L 65
5 - Drive Keypad Operation
In this chapter the parameters management is described, by using the drive keypad.
5.1 Keypad
Changes made to parameter have immediate effect on drive operation, but are not automatically stored in
permanent memory. An explicit command is required to permanently store the parameters: "C.000 Save
parameters".
Reset
Navigation
Hz A VPrg Rev Fwd
Prg
E
Reset
Navigation
Hz A VPrg Rev Fwd
Prg
E
KBG-1 (standard) KBG-LCD-.. (Optional)
Hz A VPrg Rev Fwd
STARTUP S000
Mains voltage
Parameter name
Menu
Parameter code
(Menu + number from 000 to 999)
Menu:
d
S
I
=DISPLAY
=STARTUP
=INTERFACE
F
P
A
C
=FREQ & RAMPS
=PARAMETER
=APPLICATION
=COMMAND
Hz A VPrg Rev Fwd
S.000
Prg Scroll menù: Allows navigation thruogh the drive main menu (d.xxx, S.xxx, I.xxx, F.xxx, P.xxx, A.xxx and
C.xxx). Also used to exit the editing mode of a parameter without appling the changes.
E Enter key: Used to enter the editing mode of the selected parameter or to confirm the value.
UP key: Used to scroll up through parameters or to increase numeric values while in editing mode; it can
also be used to increase motorpotentiometer reference value, when F.000 Motorpot ref parameter
is displayed (F, FREQ RAMP menu).
DOWN key: Used to scroll down through parameters or to decrease numeric values while in editing mode; it can
also be used to decrease motorpotentiometer reference values, when F.000 Motorpot ref parameter
is displayed (F, FREQ RAMP menu).
I Start key: Used to START the drive via keypad; requirements:
+24V between 22 & 8 terminals (Enable)
+24 V between 23 & 8 terminals (Run Fwd) or + 24 V between 24 & 8 terminals (Run Rev)
P.000 Cmd source sel = [1] CtlWrd & kpd parameter setting
O Stop key: Used to STOP the drive via keypad;
Keypad LED’s meaning:
PRG(Yellow Led): flashes if the parameters have not been permanently saved to memory.
REV (Green Led): reverse running (*)
Fwd (Green Led): forward running (*)
Hz, A, V(Red Leds): Indicates the unit of measurement of the parameter currently displayed (**).
Note:
(*) Green LEDs blinking denote the action of the motor stall prevention.
(**) Red LEDs blinking denote an active alarm condition.