64 AGy -L
English
Term. Designation Function
1 Digital Output 4-NO
2 Digital Output 4-COM Programmable digital relay output, default: [2] Drive OK (max 1A 30Vdc/250Vac)
3 Digital Output 4-NC
4 Digital Input 8 Programmable digital input - Default: Fault Reset src
5 Digital Input 7 Programmable digital input - Default: Ext fault src
6 Digital Input 6 Programmable digital input - Default: Freq Sel 3 src
7 Digital Input 5 Programmable digital input - Default: Freq Sel 2 src
8 COM-IN Digital Inputs Supply reference for Digital inputs (max 6mA @ +24V)
9 + 24V OUT + 24 V potential voltage reference (max 300mA)
10 0 V 24 - GND Dig. Inputs 0 V 24 reference for Digital inputs
11 0 V 24 - GND Dig. Inputs 0 V 24 reference for Digital inputs
16 Digital Output 1 Programmable digital output - Default: [51] Contactor
17 Digital Output 2 Programmable digital output - Default: [32] Freq<thr1
Term. Designation Function
18 Digital Output 3 - NO
19 Digital Output 3 - COM Programmable digital relay output
Default: [54]Brake cont, (max 1A 30Vdc/250Vac)
20 Digital Output 3 - NC
21 GROUND REF Ground shield cable reference
22 Digital Input 1 Programmable digital input - Default: Enable src
23 Digital Input 2 Programmable digital input- Default: Run Fwd src
24 Digital Input 3 Programmable digital input - Default: Run Rev src
25 Digital Input 4 Programmable digital input - Default: Freq sel 1 src
26 Analog Output 1 Programmable analog output - Default: [0] Output freq, (±10V / max 5mA)
27 Analog Input 2 Programmable VOLTAGE analog input - Default: n.a. , (±10V / max 0,5mA)
28 Analog Input 3 Programmable CURRENT analog input - Default: n.a. , ( max 20mA)
29 +10V OUT + 10 V potential voltage reference, (max 10mA)
30 Analog Input 1 Programmable VOLTAGE analog input - Default: n.a. , (±10V / max 0,5mA)
31 0 V 10 - GND 0 V 10 reference for analog inputs/outputs
32 -10V OUT - 10 V potential voltage reference, (max 10mA)
33 Analog Output 2 Programmable analog output - Default: [2] Output curr, (±10V / max 5mA)
34 COM Digital outputs Common reference for Digital outputs (open-collector)
n.a. = not assigned
+24Vdc voltage, which is used to externally supply the regulation card has to be stabilized and with a
maximum ±10% tolerance. The maximum absorption is 1A.
It is not suitable to power supply the regulation card only through a unique rectifier and capacitive filter.
ENC-EXP-AGy card
The EXP-ENC-AGy card allows the connection of a digital encoder TTL (+5V) or HTL (+24V)
Default setting = HTL (+24V).
See chapter 8 - Encoder Interface - for further information.
Caution