56 AGy -L
English
3.6 Open-Loop and Closed-Loop control section
No. 3 Programmable Analog inputs: ________ Analog input 1 ±10 V 0.5 mA max, 10 bit + sign / unipolar or bipolar (0...10V=default)
Analog input 2 ±10 V 0.5 mA max, 10 bit + sign / unipolar or bipolar (±10 V =default)
Analog input 3 0...20 mA, 4...20mA 10 V max, 10 bit (4...20mA=default)
No. 2 Programmable Analog outputs: _______ ±10 V / 5 mA max
Analog output 1 = -10...+10V, 10 bit, Frequency output absolute value (default)
Analog output 2 = -10...+10V, 10 bit, Output current (default)
No. 8 Programmable Digital inputs: ________ 0...24V / 6 mA
Digital input 8 = Fault reset src (default)
Digital input 7 = Ext fault src (default)
Digital input 6 = Freq Sel 3 src (default)
Digital input 5 = Freq Sel 2 src (default)
Digital input 4 = Freq Sel 1 src (default)
Digital input 3 = Run Rev src (default)
Digital input 2 = Run Fwd src (default)
Digital input 1 = Enable src (default)
No. 4 Programmable Digital outputs: _______ Digital outputs 1 = Contactor (default)
Digital outputs 2 = freq<thr1 (default)
Digital outputs 3 = Brake cont (default)
Digital outputs 4 = Not in alarm (default)
Note!
Dig. out. 1 / 2 > open collector type: 50V / 50mA
Dig. out. 3 / 4 > relay output type: 230Vac-1A / 30Vdc-1A
Internal voltage supply: __________________ + 24Vdc (±10 %), 50mA (Terminal 1)
+ 10Vdc (±3 %), 10mA (Terminal 29)
- 10Vdc (±3 %), 10mA (Terminal 32)
+ 24Vdc (±10 %), 300mA (Terminal 9)
No.1 Digital Encoder Input _______________ Voltage: 5/8/24 V
Type: 1 channel / 2 channels. No zero.
Max frequency: 150kHz
3.7 Accuracy
Reference value _______________________ 0.1 Hz (Resolution of Reference preset via terminals)
0.1 Hz (Resolution of Reference preset via interface)