AGy -L 55
English
Continuous
current
@400V
SLOW
Overload
factor
T1 SLOW
Overload
time
SLOW
Overload
current
T2 SLOW
Overload
pause time
@90% Cont
curr
FAST
Overload
factor
TF FAST
Overload
time [sec]
FAST
Overload
current
LOW
Frequency <
3Hz
overload
factor
LOW
Frequency <
3Hz
overload
time
[A] [sec] [A] [sec] [sec] [A] [sec]
5450 93 126.5 170.2
5550 114 155 208.6
6750 142 193.1 259.9
7900 185 251.6 338.6
71100 210 285.6 384.3
71320 250 340 457.5
81600 324 440.6
1.4 1.0
453.6
82000 400 544.0
1.4 1.0
560.0
TL2021g
2
1.83
Model
0.5
1.36 1.3660 300
Table 3.5.1-B: Overload Availability (Sizes 5450... 82000)
FastOvldCurrentLevel
SlowOvldCurrentLevel
100%ContinuousCurrentLevel
90%ContinuousCurrentLevel
Overload Level [%]
Time [sec]
TF
T1
T2
Load current must be reduced to 90% level
to allow next overload cycle
Drive current is limited to 100% level
when drive overload alarm is selected
as Ignore or Warning
Figure 3.5.1-B: Overload Duty Cycle (Sizes 5450... 82000)