AGy -L 63
English
4.3 Regulation Section
EXP-ENC-AGy (OPTIONAL)
LED Color Function
PWR
green LED turns on when the voltage + 5V is present
RS 485
yellow LED turns on when Serial interface is supplied
Connector No. of pins Function
XV 2 Reserved (Fans control)
XT 10 KGB-1 and/or KGB-LCD-A keypad connector
XENC
10
EXP-ENC-AGY optional board connection
(for encoder feedback)
XS 9 9-pole SUB-D connector of RS485 serial line
XKEY 5+1 QUIX-PRG key connection
XP 40 Reserved (power board connection)
XEXP 34 Reserved (expansion boards connection)
XD 10 Reserved (FW download connection)
Jumper Default Function
Jumper to disconnect 0V24 (regulation section)
from ground.
ON = 0V24 connected to ground
OFF = 0V24 disconnected from ground
Jumper to disconnect 0V (regulation section)
from ground.
ON = 0V connected to ground
OFF = 0V disconnected from ground
Selection of the internal/external supply of the
RS485 serial interface
ON = Serial interface supplied from the
regulation section
OFF = Serial interface supplied from external
source and galvanic insulation from the
regulation card
Terminating resistor for the serial interface
RS485:
OFF = No termination resistor
ON = Termination resistor IN
Switch Default Switch function of EXP-ENC-AGy board
S-1
OFF
OFF = HTL output logic encoder level (+24V)
ON = TTL output logic encoder level (+5V)
S-2
OFF
OFF = HTL output logic encoder level (+24V)
ON = TTL output logic encoder level (+5V)
S1
ON
S3 S4
S2
S5 S6
ON
ON
ON

Table of Contents