Cinterion
®
LTE Terminals Hardware Interface Description
4.2 Electrical Specifications of the Application Interface
60
ELSxT_HID_v04 2018-09-04
Confidential / Preliminary
Page 50 of 102
4.2.4 GPIO Interface
Table 23: GPIO interface specifications (requirements)
Function Signal name IO Signal form and level Comment
8-pin, 12-
pin connec-
tors for:
GPIO,
Power,
DAI,
I
2
C and
ASC1, SPI
GPIO 6-8
GPIO 11-13
GPIO 20-21
GPIO 22-23
IO V
OL
max = 0.1V at I = 100µA
V
OL
max = 0.55V at I = 32mA
V
OH
min = VCCref - 0.1V at I = 100µA
V
OH
min = VCCref - 0.4V at I < 12mA
V
OH
min = VCCref - 0.7V at I < 32mA
V
IL
max = 0.3 * VCCref
V
IH
min = 0.7 * VCCref
If unused keep lines
open.
Please note that some
GPIO lines can be config-
ured for functions other
than GPIO:
GPIO6/GPIO7: PWM
GPIO8: Pulse Counter/
WD_RETRIG
GPIO20-23: PCM/DAI
VCCref I Vimax = 5.5V
Vimin = 1.8V
Input current has to at least match the
positive output current required by all
configured and used GPIO lines.
For level adjustment.
E.g., connect 5Vout for
5V IO operation.
Must be connected to
1.8...5.5V if employing
signals from GPIO con-
nector.
GND -- --
TXD1/
SPI_MISO
IV
OL
max = 0.1V at I = 100µA
V
OL
max = 0.55V at I = 32mA
V
OH
min = VCCref - 0.1V at I = 100µA
V
OH
min = VCCref - 0.4V at I < 12mA
V
OH
min = VCCref - 0.7V at I < 32mA
V
IL
max = 0.3 * VCCref
V
IH
min = 0.7 * VCCref
If unused keep lines
open.
SPI interface is not avail-
able for ELS31T-V/J.
RXD1/ SPI_-
MOSI
O
CTS1/
SPI_CS
O
RTS1 I
+5Vout O 5V, +0.05V, -0.2V
Ioutmax = 100mA
Regulated output for
external supply. Can be
connected to VCCref.
If unused, keep open.
DSR0/
ADC1_IN
(Analog-to-
Digital con-
verter)/ SPI_-
CLK
IR
I
= 1MΩ
V
Imax
= 0V...VCCref + 0.3V
Valid range 0V…5V
Resolution 1024 steps
Tolerance 0.3%
ADC1_IN can be used as
input for external mea-
surements.
If unused keep line open.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Cinterion ELS61T-US and is the answer not in the manual?

Gemalto Cinterion ELS61T-US Specifications

General IconGeneral
BrandGemalto
ModelCinterion ELS61T-US
CategoryTouch terminals
LanguageEnglish

Related product manuals