48
Note the spark in the spark gap window. It should be strong
and continuous, not intermittent, acrossa preset 8mm(0.32in) gap.
Allow the spark to jump the test gap for at least five minutes
continuously. To insure proper operation under the temperature of
actual riding.
Electronic tester
Ignition coil testing lead
Use portable tester to check it.
Test the resistance between igntion ground wire and spark plug cap.
Ignition coil second resistance12-18 KQ
MAGNETO EXCITING COIL
z remove the right frame side cover
z disconnect the exciting coil lead wire(black with red tracer).
z Using a pocket tester, measure the resistance between the B/R
lead wire and ground. If the resistance checked is incorrect, replace
the coil.
Exciting coil restance140-220