28142 Rev 15 ADJUSTMENT
Gentherm Global Power Technologies Page 40
8 ADJUSTMENT
This section describes how to adjust the Model 5220 Thermoelectric generator.
NOTE:
Typical fuel pressure settings are 130 - 144 kPa (18.5 - 21 PSI) for natural gas
and 125 - 140 kPa (18 - 20 PSI) for propane.
NOTE:
Good record keeping is necessary for long term follow-
up. Use the TEG
Performance Log, located at the end of this manual, for recording details each
time adjustments are made, or service is carried out.
Figure 22Change in Fuel Gauge Pressure vs Elevation Above Sea Level
TEG power output is determined by the flow of air and fuel into the burner. Follow these
procedures in the order given to adjust the TEG’s power output.

Table of Contents