Transport, installation and commissioning
Method
1. Select Service menu > Calibration.
2. Select the mill from the dropdown menu
3. Hold a suitable container under the outlet of the mill and
press [Start].
4. Weigh the delivered quantity and enter the weight in the
input field.
5. Confirm the entry with [ Save].
6. After calibration, reinsert the brewer with the two hoses and
the coffee grounds container.
7. Close the automatic door and lock it with the key.
5.3.10 Conduct a test sale
Method
1. Unlock and open the automatic door with the key.
2. Select Service menu > Counter readings.
3. Press [Activate test sale].
4. Close the automatic door and lock it with the key.
After closing the vending machine door, the vending
machine is in "test sale" mode for 10 minutes.
Calibrating the coffee grinder