58
Method
1. Clean mixing chamber (4), mixer disc (8), powder trap (7),
rinsing nozzle (2) and separating nozzle (3) thoroughly with
hot water and dry well with a clean tea towel.
2. Knock out the powder slide (1). If necessary, rinse under
hot running water to remove heavy soiling.
3. ATTENTION! Danger of loss of function! Residues of
water can lead to product adhesions. Dry the cleaned
powder chute thoroughly.
Method
1. Align the marking point of the mixer disc (8) with the
flattening of the shaft (9) and push the mixer disc (8) onto
the shaft (9).
2. Install the powder trap (7).
3. Insert the induction nozzle (2) into the mixing chamber (4).
4. Place the separating nozzle (3) on the mixing chamber (4).
5. Install mixing chamber (4) and press firmly on.
6. Turn flange (6) clockwise to the detent position (from 5
o'clock to 6 o'clock).
Depending on the model, insert either the outlet angle (5) or
the outlet hose and check for tight fit.
7. Install the powder chute (1) from the front.
8. Check whether all components have been assembled
appropriately.
9. Close the automatic door and lock it with the key.
10. Running the “Complete flush” program (Complete flush
program on page 53).
7.13 Cleaning the beverage outlet
Method
1. Unlock and open the automatic door with the key.
2. Unlock the hose dispenser with your finger and pull it out to
the front.
3. Pull off the hoses.
4. Remove the drip tray.
5. Remove the collection box.