5 Starting up the control
Plug-in or switch on
the mains supply line
DES: Rapid adjustment of limits
1. Check rotating direction
2. Move to final limit position open 3. Save limit position
4. Move to final limit position close 5. Save limit position
Note!
Fast adjustment is complete, "Hold-to-run" door operating mode active
Change of OPEN/CLOSE limit position via Parameter "1.1" to "1.4"
Pre-limit safety edge adjusts automatically
Changing the pre-limit position is possible via Parameter "1.5"