EasyManua.ls Logo

GFA TS 971 - 10 Functional Description; X: 24 V DC Voltage Supply; X1: Mains Supply Line for Control and External Supply

GFA TS 971
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Functional description
X: 24 V DC voltage supply
Connection of external devices such as photo cell, radio receiver, relay, etc. via the 24 V and
GND terminals.
Attention Damage to components!
Total current consumption of external devices: maximum 350 mA
X1: Mains supply line for control and external supply
Mains supply line for control
Connection via terminals X1/1.1 to X1/1.4 and PE.
Various mains connections: 3 N~ , 3~, 1 N~ for symmetric and asymmetric motors.
Note!
Pay attention to the "Mains supply connection" and "Mains supply connection to
control" descriptions
External supply
Connection of external devices for 230 V, such as photo cell, radio receiver, relay, etc. via
terminals X1/1.8 and X1/1.9.
Note!
Mains supply: 3 N~400 V or 1 N~230 V, symmetric
Protection via F1, 1.6-A time-lag micro-fuse

Table of Contents

Other manuals for GFA TS 971

Related product manuals