EMERGENCY operation
Warning!
"Hold-to-run" door operating mode:
The door must be fully visible from the operating point
EMERGENCY operation allows for moving the door to a required position by bypassing faults
with the signal transmission of the safety device.
EMERGENCY operation is activated after 7 seconds of continuously pressing the STOP
push-button and indicated by the flashing display.
Note!
The door cannot be moved in case of "F1.3" and "F1.4" fault indications for
reasons of operating safety.
Activation of EMERGENCY operation: Use keypad on control to continuously
press the STOP push-button, while simultaneously pressing the OPEN or
CLOSE push-button to move the door
X3: Input, emergency stop
Connection of an emergency stop control device as per EN 13850 or an evaluation unit for an
anti-trap safety device. The F1.4 fault indication appears upon activation.
Note!
FI-drive units: Drive units are de-energised as a result of an emergency stop