2 Technical data
Series TS 971
Dimensions W x H x D 155 x 386 x 90 mm
Installation Vertical
Vibration
Free of vibration
Installation
Operating frequency 50/60 Hz
Supply voltage
1 N~220 V, PE
3 N~220-400 V, PE
3~220-400 V, PE
Output power for drive unit, maximum 3 kW
Protection per phase, on-site 10-16 A
24 V DC
External supply voltage:
(internal electronic protection)
0.35 A
1 N~230 V
External supply voltage: X1/L, X1/N
(protection via F1 micro-fuse)
1.6 A time-lag
24 V DC
Control inputs
Type 10 mA
Type of relay contacts (2 pcs)
Max. current of 1A at 230VAC, and 0.4A at 24VDC
(The use of LED lamps is recommended.)
Potential-free changeover
contacts
230 V AC
Loading of relay contacts,
ohmic/inductive
1 A
Control power consumption 10 VA
Temperature range
Operation: -10..+50
Storage: +0..+50
°C
Air humidity
to 93 %
non-condensing
Protection class of housing IP65
Compatible GfA limit switch DES
Integrated radio receiver
WSD / radio transmitter
2.4GHz / 434MHz

Table of Contents