DU/FI settings
DU/FI settings
OPEN output speed
Output speed in rpm
CLOSE output speed
Output speed in rpm
Increased CLOSE output speed
To opening height of 2.5 m
Output speed in rpm
0 = Off
Changeover position to CLOSE output speed
(observe minimum opening height of 2.5 m!)
OPEN/CLOSE door movement
OPEN acceleration
DU Steps of 1.0 seconds
FI Steps of 0.1 seconds
CLOSE acceleration
DU Steps of 1.0 seconds
FI Steps of 0.1 seconds
OPEN deceleration
DU Steps of 1.0 seconds
FI Steps of 0.1 seconds
CLOSE deceleration
DU Steps of 1.0 seconds
FI Steps of 0.1 seconds
OPEN/CLOSE crawling speed
Output speed in rpm