Note: Ground adjustment!
Automatic compensation of rope elongations or changes in ground conditions of
approx. 2-5 cm
Do not use with overrun correction
Do not use with pneumatic switch
Note: Reversing upwards in the overrun area!
To maintain the operating forces in the pre-limit area
At high speeds
Function for FI-drive units not necessary
Overrun correction function
Menu "2.2":
Automatic limit switch correction to achieve a constant CLOSE position.
Function Overrun correction
"0" Off
"1" On
Note: Overrun correction!
Do not use with ground adjustment