Faults
Display: "F" and code
Status
code
Fault description Measures for fault correction
8k2 safety edge system has been activated.
Check whether the safety edge system is
correctly functioning.
Check whether the connection cable has short-
circuited.
8k2 safety edge system is defective.
Check whether the safety edge system is
correctly functioning.
Check whether the connection cable is
connected.
1k2 safety edge system has been activated.
Check whether the safety edge system is
correctly functioning.
Check whether the connection cable is
connected.
1k2 safety edge system is defective.
Check whether the safety edge system is
correctly functioning.
Check whether the connection cable has short-
circuited.
1k2 testing is negative.
Testing is activated in the lower final limit
position.
"WSD" wireless safety device or optical safety
edge system has been activated or is defective.
Check whether the safety edge system is
correctly functioning.
Check the "WSD" door module.
OPEN emergency stop switch reached.
In the voltage-free state, move the door back via
emergency manual operation.
CLOSE emergency stop switch reached.
In the voltage-free state, move the door back via
emergency manual operation.