Location 21
Code No. 549758
Rev. nº 10/0418
3.1. General information and location
To ensure that the machine functions properly and safely, the location and installation instructions set
out in the corresponding sections must be complied with, in particular:
Hazard warnings
Installing the different protection elements indicated
Indications relating to the location of the machine
Indications relating to the areas of use indicated in the corresponding plans
Size and connection of the ducts for the heating supply: gas
Size and connection of the electricity supply conduits
Size and connection of the exhaust duct.
Technical features on the dryer and complementary information on the installation Chapter 4 and 5.
CAUTION!
THE OPERATIONS INVOLVED IN LOCATING THE MACHINE MUST BE CARRIED OUT BY AUTHORISED
TECHNICAL SERVICES.
The machine must be installed on a flat floor surface that is perfectly even and capable of supporting the weight
of the machine.
A concrete floor with a resistance equal to or greater than 250 kg/cm
2
(4,000 psi) is recommended.
The location surface must be free of any inflammable covering.
Take into account the minimum amount of space required for use. This space facilitates good working
conditions and machine maintenance. Refer to operating zones and values in Section 3.2.
If the dryers are installed on metal surfaces the aforementioned surfaces must be earthed by an electric
connection independent to the earth connection of the machine.