Connecting the machine 49
Code No. 549758
Rev. nº 10/0418
5.1.2. Models with breaker switch
Figure 5.1: Example of a connection for electrically heated machines connected to a 3Ph + N + Earth line.
Machines with gas heating
On these models, the connection is ALWAYS SINGLE-PHASE (1Ph+N) or TWO-PHASE. (2Ph). However,
they can be connected to a three-phase installation. (See the wiring diagrams in Section 4.2).
Models ED900 and ED1250 gas and steam
Place the breaker switch handle in the OFF position.
Remove the isolator switch cover.
Remove the caps covering the breaker switch
terminals.
Insert the electric cable inside the dryer through the
hole (Fig. 5.2/E).
Fig. 5.2
Models ED260, ED340, ED460 and ED660
Place the breaker switch handle in the OFF position.
Remove the dryer top cover securing screws and
remove it to allow removal of the rear cover.
Remove the upper rear cover.
Remove the caps covering the breaker switch terminals.
Insert the electric cable inside the dryer through the hole
(E, Fig. 4.1).
Connect the power supply cable to the terminals of the
breaker switch (Figure 5.1). Replace the covers
protecting the terminals.
Connect the earth cable.
Assemble all the covers and fix them. Assemble the
switch handle.
Check that the cable or the cable protection conduit is
correctly attached to the back cover of the machine.
Fig. 5.1