Set-up 5
0020237648_03 Installation manual 11
5.1.2.2 Scope of delivery, article number
0010035513
754
Ø167
40
85
60
1
234
6 5
1 Wall collar, 100 dia-
meter (2 pcs)
2 Horizontal wall/roof duct
3 40 mm clamp
4 87° elbow
5 Screws (8 x)
6 Seal
5.1.2.3 Shortening the air/flue gas pipe
A + 55
13
Danger!
Risk of poisoning due to escaping flue
gas.
Flue gas can escape if a flue gas pipe is dam-
aged.
Take care that the flue gas pipe is not
damaged when shortening.
1. Shorten the flue gas pipe and the air pipe by the same
length when they are assembled.
Note
Disassembling the flue gas pipe and the air
pipe damages the latching lugs in the ter-
minal.
Condition: Additional extensions and elbows required
Install the extensions. ( Page 28)
All of the sleeves for the flue gas pipe must point
towards the terminal.
Install the 45° elbow. ( Page 31)
Install the 87° elbow. ( Page 32)
5.1.2.4 Installing the wall duct
13
1
A
1. Drill a hole.
Diameter: 125 mm
Clearance Article number
0010035513 0020219523
0010031041
A 87 mm 140 mm
Note
If the wall duct can be accessed from the
exterior of the building, you can drill the hole
with a diameter of 110 mm and install the
wall duct with the wall collar from outside.
3
2
2. Position the flexible external collar (2) between the two
seams (3).
3. Slide the air/flue pipe (1) with the flexible external collar
through the wall.
4. Pull the air/flue pipe back until the external collar lies
fully on the external wall.
5. Secure the air/flue pipe with mortar and leave the mor-
tar to harden.
6. Install the wall collar on the inside of the wall.
7. Connect the wall/roof duct to the product using ex-
tensions, elbows and, if required, a sliding sleeve.
( Page 13)