5 Set-up
20 Installation manual 0020237648_03
5.1.10.3 Scope of delivery
1 87° elbow (2 x)
2 Pipe clamps (3 x)
3 Extension (1 m) without
sleeve
4 Extension (1 m) with
sleeve
5 End pipe
6 Opening piece
7 Wall collar (only in-
cluded in the variable
terminal kit, black)
– Variable terminal kit, black, article number 0020219531
– Variable terminal kit, white, article number 0020219532
(no wall collar)
5.1.10.4 Installing the black variable terminal kit
(VTK)
▶ Proceed as described in section "Installing the black ter-
minal (change of colour)" (→ Page 15).
5.1.10.5 Installing the white variable terminal kit
(VTK)
1. Release the catch between the opening piece and the
end pipe.
2. Pull the end pipe from the opening piece.
3. Slide the first 87° elbow onto the opening piece until the
87° elbow audibly clicks into place.
5.1.10.6 Installing extensions
1. Install the flue system from the 87° elbow to the flue
outlet.
– Begin with the extension with the sleeve. To be able
to install the second 87° elbow with the end pipe,
you must install the extension without a sleeve last.
– Allow expansion space of 1 cm in each sleeve.
– Ensure that all pipe joints are absolutely leak-tight.