Certified air/flue systems and components 3
0020237648_03 Installation manual 7
3 Certified air/flue systems and components
3.1 System overview, 60/100 mm diameter
Article number Air/flue systems, concentric
0020219523
1), 3)
0010031041
1)
Horizontal wall/roof duct, 0.7 m
0020219524
1), 3)
Horizontal telescopic wall/roof duct (only available in black)
0020219526
1)
Direct, rear-side, telescopic flue system
0020230604
2)
Vertical roof duct
0010035513
2)
Horizontal wall duct, 0.7 m for multi-storey buildings
1) In accordance with the construction regulation, installation in buildings higher than 18 m is not permitted
2) In accordance with the construction regulation, installation in buildings higher than 18 m is permitted
3) Only for boilers with an upper cover plate with more than eight fastening holes
3.1.1 Components
The following table lists the air/flue systems that are permitted as part of the system certification, along with their certified
components.
Article num-
ber
0020219523
0010031041
0020219524 0020219526 0020230604 0010035513
Connector (including air pipe clamp) 0020257015 –– –– –– X X
Connector (including air pipe clamp) 0010031029 –– –– –– X ––
Extension, 0.5 m (including air pipe
clamp)
0020257007 X X –– X X
Extension, 1.0 m (including air pipe
clamp)
0020257008 X X –– X X
Extension (stainless steel), 1.0 m (includ-
ing air pipe clamp)¹
0010035515 X –– –– –– X
Extension, 2.0 m (including air pipe
clamp)
0020257445 X X –– X X
87° elbow, (including air pipe clamp) 0020257009 X X –– X X
45° elbow (2 pcs), (including air pipe
clamp)
0020257010 X X –– X X
Sliding sleeve 0020267684 –– –– –– X ––
Telescopic extension with air pipe clamp 0020267683 –– –– –– X ––
Pipe clamps (5 pcs), DN100 0020267923 X X –– X X
Fixing brackets (5 pcs), adjustable,
100 mm diameter
0020267924 X X –– X X
Flat roof penetration collar 0020199443 –– –– –– X ––
Pitched roof tile 0020258676 –– –– –– X ––
Black terminal set for horizontal air/flue
pipe
0020219538 X X –– –– ––
Variable terminal set (VTK), black 0020219531 X X X –– ––
Variable terminal set (VTK), white 0020219532 X X –– –– ––
Extension for variable terminal set (VTK),
1.0 m, black
0020219541 X X X –– ––
Extension for variable terminal set (VTK),
1.0 m, white
0020219542 X X –– –– ––
Deflector set, DN 60, PP, black 0020219535 X X X –– ––
Deflector set, DN 60, PP, white 0020219536 X X –– –– ––
45° elbow for variable terminal set
(VTK), black (2 pcs)
0020219553 X X X –– ––
45° elbow for variable terminal set
(VTK), white (2 pcs)
0020219554 X X –– –– ––
1 In accordance with the construction regulation, installation on the external wall in buildings higher than 18 m is permitted. The sleeve
end of the extension must protrude at least 60 mm from the wall to comply with fire-protection requirements.