EasyManua.ls Logo

Glow-worm ENERGY - Installing the pitched-roof duct

Glow-worm ENERGY
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Set-up
24 Installation manual 0020237648_03
5.1.11.7 Installing the pitched-roof duct
Ø 100
20 - 50°
A
1
2
3
A Position of the internal
flue pipe seal
1. Determine the installation site of the roof duct so that
there is sufficient distance behind the product in order
to connect the product to the heating installation.
2. Insert the pantile (2).
3. Insert the roof duct (1) through the pantile from above
and push it down until the cover plate is seated firmly.
Ensure that the internal flue pipe seal lies above the
roof.
4. Align the roof duct vertically.
5. Secure the roof duct to the roof construction using the
fixing bracket (3).
6. Connect the roof duct to the product using extensions,
elbows and, if required, a sliding sleeve. If you do not
insert a sliding sleeve, you must always install the 48
mm clamp directly on the product.
7.
Alternatives 1:
Condition: Roof duct with extension
Install 60/100 mm diameter extensions. ( Page 28)
Install the 45° elbow. ( Page 31)
Install the 87° elbow. ( Page 32)
Install the sliding sleeve. ( Page 28)
Connect all of the pipe joints with air pipe clamps.
( Page 37)
7.
Alternatives 2:
Condition: Roof duct without extension
Install the sliding sleeve. ( Page 28)
5.1.11.8 Installing the flat-roof duct
Caution.
Risk of damage to the structure of the
building.
As a result of improper installation, water may
penetrate the building and cause material
damage.
Observe the definitions in the directives
for the planning and implementation of
roofs with seals.
1
2
4
3
A B
C
Ø120
Ø100
A Cold roof
B Warm roof
C Position of the internal
flue pipe seal
1. Determine the installation site for the roof duct.
2. Insert the flat roof penetration collar (2).
3. Glue the flat roof penetration collar firmly in place.
4. Insert the roof duct (1) through the flat roof penetration
collar from above and push it down until seated firmly.
Ensure that the internal flue pipe seal lies above the
roof.
5. Align the roof duct vertically.
6. Put the cover plate (3) on.
7. Secure the roof duct to the roof construction using the
fixing bracket (4).
8. Connect the roof duct to the product using extensions,
elbows and, if required, a sliding sleeve. If you do not
insert a sliding sleeve, you must always install the 48
mm clamp directly on the product.
9.
Alternatives 1:
Condition: Roof duct with extension
Install 60/100 mm diameter extensions. ( Page 28)
Install the 45° elbow. ( Page 31)
Install the 87° elbow. ( Page 32)
Install the sliding sleeve. ( Page 28)
Connect all of the pipe joints with air pipe clamps.
( Page 37)
9.
Alternatives 2:
Condition: Roof duct without extension
Install the sliding sleeve. ( Page 28)

Table of Contents