71
10 Technical Parameters
User Manual V1.1-2022-12-20
Technical Parameters GW5KN-ET GW6.5KN-ET GW8KN-ET GW10KN-ET
Operating Temperature Range (℃) -35 ~ +60 -35 ~ +60 -35 ~ +60 -35 ~ +60
Relative Humidity 0~95% 0~95% 0~95% 0~95%
Max. Operating Altitude (m) 4000 4000 4000 4000
Cooling Method Natural Convection
User Interface LED, APP LED, APP LED, APP LED, APP
Communication with BMS
*5
RS485, CAN RS485, CAN RS485, CAN RS485, CAN
Communication with Meter RS485 RS485 RS485 RS485
Communication with Portal WiFi / WiFi+LAN (Optional) / 4G (Optional)
Weight (kg) 24 24 24 24
Dimension (W×H×D mm)
415×516×180 415×516×180 415×516×180 415×516×180
Noise Emission (dB) <30 <30 <30 <30
Topology Non-isolated
Self-consumption at Night (W)
*6
<15 <15 <15 <15
Ingress Protection Rating IP66 IP66 IP66 IP66
DC Connector MC4 (4~6mm
2
)
AC Connector Feed-Through Terminal Blocks UW10
Environmental Category 4K4H 4K4H 4K4H 4K4H
Pollution Degree III III III III
Overvoltage Category DC II/AC III DC II/AC III DC II/AC III DC II/AC III
Storage Temperature (℃) -40 ~ +85 -40 ~ +85 -40 ~ +85 -40 ~ +85
The Decisive Voltage Class (DVC)
Battery: C
PV: C
AC: C
Com: A
Mounting Method Wall Mounted
Certication
*7
Grid Standards
VDE-AR-N 4105, VDE 0126-1-1, EN 50549-1, G98, G99,
G100, CEI 0-21
Safety Regulation IEC62109-1&2
EMC
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4,
EN61000-4-16, EN61000-4-18, EN61000-4-29