RunMode
Home Home
Home
System System
System
Off Off
Off
Thisisthehomescreenwhenthesystemisoff.
Thisscreendisplaysactualtemperatures,actual
pressuresatthe󰘱uidmanifold,jogspeed,coolant
temperature,andnumberofcycles.
Home Home
Home
System System
System
Active Active
Active
Whenthesystemisactive,thehomescreendisplays
actualtemperatureforheatzones,actualpressures
atthe󰘱uidmanifold,coolanttemperature,jogspeed,
thenumberofcycles,alongwithallassociated
controlsoftkeys.
Usethisscreentoturnonheatzones,view
coolanttemperature,starttheproportioner,stopthe
proportioner,parkthecomponentApump,enterjog
mode,andclearcycles.
NOTE: NOTE:
NOTE:
Thescreenshowndisplaysinletsensor
temperaturesandpressures.Thesewillnotbe
shownonmodelswithoutinletsensors.
NOTE: NOTE:
NOTE:
Thescreenshowndisplays󰘱owbarsandthe
󰘱owratio.Theverticalbarsindicatethelevelof󰘱ow
throughthemeters.Thenumericalratioindicates
theratioofA-sidecomponenttoB-sidecomponent
(ISO:RES).Forexample,iftheratiois1.10:1,
theproportionerispumpingmoreA-sidecomponent
(ISO)thanB-sidecomponent(RES).Iftheratiois
0.90:1,theproportionerispumpingmoreB-side
component(RES)thanA-sidecomponent(ISO).
Home Home
Home
System System
System
With With
With
Error Error
Error
Activeerrorsareshowninthestatusbar.Theerror
code,alarmbell,anddescriptionoftheerrorwill
scrollinthestatusbar.
1.Press toacknowledgetheerror.
2.Seeforcorrectiveaction.