6. DISASSEMBLY AND REASSEMBLY
How to reinstall the X-motor
(1) Attach the X-motor to the left side plate.
(2) Connect the X-motor cable to its connector(s) on the main board.
CE5000-40/60: ........ Connect the cables to connector J7 and J10 on the main board.
CE5000-120/120AP: Connect the cables to connector J1102 and J1104 on the X-motor relay board.
(3) Fasten the X-motor harness with the wiring harness tie-wrap.
(4) Hang the X-drive belt on the X-drive pulley.
(5) Attach the X-motor pulley to the X-motor.
(6) Tighten the two M3L4WP set screws holding the X-motor pulley.
(7) Spread a suitable quantity of Loctite 222 on the M3L4WP set screw holding the X-motor pulley.
(8) Use the force gauge to pull the X-drive motor pulley flange with a 1.2 kg to 1.3 kg force.
(9) Tighten the mounting screws that hold the X-motor.
(10) Spread a suitable quantity of the Shinetu silicon grease G501 on the X-motor pulley.
(11) Move the X-drive pulley and check the tension of the X-drive belt.
(12) Reattach the other parts in the reverse order in which they were detached.