CE5000-UM-251-9370 7-5
7. ELECTRICAL ADJUSTMENTS
Note: When adjusting the pen force, it is important to do it quickly. Delaying the pen force adjustment
changes the temperature of the actuator and causes artificially lower readings. When this happens the
actual pen force may be higher than the specification. This is especially true for the upper pen force
adjustment.
(13) Press the NEXT key to complete this adjustment.
Specification of the actual pen force
Specified pen force Actual force range Remark
10g 8 to 12g
40g 36 to 44g
120g 110 to 130g
300g 280 to 320g
450g 430 to 470g Only for the CE5000-120