CS510/IS210-UM-251-9370 8-21
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
8.20 Data Controller Board
When replacing the data controller board, perform the software adjustment to obtain the former setting values from
the data controller board.
Detaching the data controller board
(1) Detach the right and left side covers (see Sections 8.1 and 8.2).
(2) Detach the front guide assembly (see Section 8.4).
(3) Disconnect all the connectors on the ethernet board.
(4) Remove the four M3L6 binding head screws holding the ethernet board bracket and then detach the
ethernet board with ethernet board bracket from the main unit.
M3L6 binding head screw
Ethernet Board
Ethernet Board Bracket
(5) Remove the M3L6 binding head screw holding the cable bracket and then detach the cable bracket from
the main unit.
M3L6 binding head screw
Cable Bracket