CS510/IS210-UM-251-9370 10-10
10. ADJUSTMENTS USING THE SOFTWARE
10.4.2 Feed distance adjustment
In the following cases, perform this adjustment.
When the distance is different in the direction of the feed.
When you replaced the main board.
When you replaced or removed the CIS sensors.
When you replaced or removed the feed motor.
When you replaced or removed the feed rollers.
How to perform the feed distance adjustment
(1) Prepare the CS600/500/IS200 Test Chart.
(2) Measure the distances between the C010 and the C090 points in the CS600/500/IS200 Test Chart with
a glass scale. And then record it.
(3) Run the software. (See page 10-1) This is not necessary when the software is running already.
(4) Select "Adjust Feed Distance" from the "Adjust" menu.
(5) The following dialog box will appear. Correctly insert the CS600/500/IS200 test chart to the scanner,
and then click the "Scan" button.