Calibration of the F-Mark
Perform the calibration of the F-Mark for correctly read the crop mark.
If disconnect the F-Mark from the CE6000Plus or change the operation computer, perform the
calibration of the F-Mark from the ʻCalibrationʼ button in the iMark software.
1
Lower the “Set Lever” of CE6000Plus, and load the “Calibration Sheet” into the CE6000Plus.
Then rise the “Set Lever” of CE6000Plus, and press the “2” button on the control panel
of CE6000Plus.
“2” button on the control panel
NOTICE
If finished using the accessory calibration sheet, the print data file ”caliblack.pdf for
calibration sheet is included in the accessory CD. Print this data to the label media for
using the calibration of the F-Mark.
Set the Cutter Plunger to the CE6000Plus, and press the “Calibration button in the iMark
software.
NOTICE
For the how to set the Cutter Plunger to the Cutting Plotter CE6000 Plus and how to
adjust the blade length of Cutter Plunger, refer to the Userʼs manual of CE6000Plus.
When perform the calibration of the F-Mark, attach the Cutter Plunger to the back
side position (for Adhesive Cutting).
Set Lever of CE6000Plus
When load the calibration sheet into the
CE6000Plus, load the calibration sheet at the
center of left and right Push Roller of
CE6000Plus
If the tip of calibration sheet is aligned with the
tip of F-Mark, the calibration sheet can be load
the straight into the CE6000Plus.
Back side:
for Adhesive Cutting
Cutter Plunger