With the XY adjustment, you can reach the maximum precision on the
bottom part of the print.The digital printers are most cases affected by
some distortions, the optical detection of two crop marks, on our
system allows an high precision neat the crop marks, while some
supplemental setting is useful to compensate other distortion on the
print, the distortions are often constant for each printer.
L :The “L” parameter sets the cut positon in the upper left area.
Input units:0.1mm, Setable values:-30 to 30 (-3mm to 3mm).
R :The “R” parameter sets the cut position in the upper right area.
Input units:0.1mm, Setable values:-30 to 30 (-3mm to 3mm).
Height :The “Height” parameter expands the cut path on the height.
Input units:0.1mm, Setable values:-100 to 100 (-10mm to 10mm).
Width :The “Width” parameter expands the cut path on the width and when used cut
without the detection of the crop marks.
Input units:0.1mm, Setable values:-100 to 100 (-10mm to 10mm).
NOTICE:
Be sure to perform the “Cut Test” after inputted parameters to confirm the cut position.
In the above figure, the cutting position is shifted the upward and rightward from the printed
Position.
In this case,
inputted the -6 to “R”
and inputted -2 to “Height”.