80
Battery
NiMH, Alkaline or Ni-
Cad
Loads low battery profile for each
different battery type.
Lo Batt Alert 0-60 seconds
Controls critical battery audible
alert. 0=off.
Battery Info SEL
Displays current battery voltage,
DAC value and charge time re-
maining if battery is charging.
Atten Mode Global or Normal
The attenuator reduces the amount
of signal at the receiver input. This
helps reduce interference from
strong nearby transmitters. Global
attenuator mode applies attenua-
tion radio-wide, regardless of in-
dividual object settings. In Normal
attenuator mode, the attenuator
follows the individual object attenu-
ator setting.
Global Atten On or Off
When the ATTEN mode is set to
Global, this controls whether the
Global attenuator is on or off.
Clear Hits SEL Press SEL to clear all hit counters.
Hit Counts Yes or No
Turns the hit counter feature on or
off.
Dflt ScanList 0-22
Sets default destination Scan Lists
for new objects and CONV Stor
from Searches, Spectrum Sweeper
and Tune. Use 1-20 for “normal”
Scan Lists 1-20. Use 0 for the “ns”
(not scanned) Scan List (no Scan
List mappings are specified). Use
21 for the FAV Scan List. Use 22 for
the SKYWARN Scan List.
Priority On or Off
Turns Priority Scan On or Off. Pri-
ority Scan can also be toggled by
pressing FUNC PRI while scan-
ning.
WxPri
O f f , 1 6 2 . 4 0 0 0 0 ,
162.42500, 162.45000,
162.47500, 162.50000,
162.52500, 162.55000
Turn off the weather priority. Or,
select weather priority frequency
then the scanner watches selected
weather alert signal.
Scan Lists SEL
Enters sub menu for Scan List set-
tings and status
SRCH L/Outs SEL
Enters sub menu for review, editing
or deletion of search lockout fre-
quencies