EasyManua.ls Logo

GREEN INSTRUMENTS G16 - User Manual

Default Icon
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
G16
Smoke Density Monitor
Instruction Manual
Document ID number.: 02891

Table of Contents

Questions and Answers

  • S
    Steven ShieldsAug 11, 2025
    What to do if my GREEN INSTRUMENTS G16 Boating Equipment shows incorrect opacity level?
    • D
      Danielle WilliamsAug 11, 2025
      If your GREEN INSTRUMENTS Boating Equipment shows an incorrect opacity level, several factors could be at play. First, the alignment between the transceiver and reflector might have shifted due to vibration or impact; realign them, checking through the duct after removing the lenses. Second, the lenses could be dirty; clean them using a cleaning pad (part no. 02398). Third, the transceiver might be damaged, necessitating replacement. Fourth, zero and/or span might have drifted, requiring recalibration. Finally, the scanning range might be out of range; consult the system specification.
  • N
    Nancy KnoxAug 18, 2025
    What to do if GREEN INSTRUMENTS G16 does not give an alarm despite opacity between the lenses?
    • N
      Nicholas HernandezAug 18, 2025
      If your GREEN INSTRUMENTS Boating Equipment fails to alarm despite opacity between the lenses, it could be due to incorrect alarm level settings; adjust these settings at the control and monitoring Unit. Alternatively, there may be damaged or faulty parts that need replacement.
  • G
    Gary BondAug 27, 2025
    Why is my GREEN INSTRUMENTS G16 showing an incorrect alarm level?
    • N
      nathan19Aug 27, 2025
      An incorrect alarm level on your GREEN INSTRUMENTS Boating Equipment is caused by incorrect alarm level settings. You should change the settings at the control and monitoring Unit.
  • A
    Andrea LeeSep 2, 2025
    How to fix no display on GREEN INSTRUMENTS G16 Boating Equipment?
    • J
      Janice GarciaSep 2, 2025
      To resolve a 'no display' issue on your GREEN INSTRUMENTS Boating Equipment, check the power supply to ensure it is connected to the correct voltage.

Summary

G16 Smoke Density Monitor Specifications

Control and Monitoring Unit Specs

Details the specifications for the G16 Control and Monitoring Unit.

Transceiver and Air Module Specs

Details the specifications for the Transceiver and Air Module.

Reflector and Air Module Specs

Details the specifications for the Reflector and Air Module.

Safety Aspects

General Safety Precautions

Covers critical warnings regarding voltage, circuit protection, earth, and installation.

Laser Safety Warning

Warns about laser radiation hazards during operation.

Installation

Standard Installation

Details the standard procedure for installing the G16 Smoke Density Monitor.

Purge Air System

Details on connecting and configuring the purge air system for the monitor.

Electrical Connections Overview

Overview of electrical connection requirements for the system.

Menu Structure & Configuration

Laser Alignment Procedure

Procedure for setting and aligning the laser beam for accurate measurement.

Transceiver Calibration Procedures

Details zero calibration and automatic/manual span calibration procedures.

Calibration Procedures

Performing Zero Calibration

Procedure for performing zero calibration without obstructions.

Performing Auto Span Calibration

Details the automatic span calibration process after zero calibration.

Performing Manual Span Calibration

Manual procedure for span calibration by blocking the light beam.

Commissioning

GREEN INSTRUMENTS G16 Specifications

General IconGeneral
BrandGREEN INSTRUMENTS
ModelG16
CategoryBoating Equipment
LanguageEnglish