Menu Structure & Configuration
32
Select an alarm and press Info, an alarm info screen with information about the current
selected alarm and suggestion to solve the alarm condition as shown on Figure 6-12 will
appear.
Figure 6-12: Alarm Info Screen - e.g, Not aligned Alarm
The full alarm list is as follow:
General error on sensor.
Check if a more specific error is present on the
same sensor.
If not replace the sensor.
Opacity warning level threshold reached. Note
this alarm will be set as soon as the sensor de-
tect the high level.
Opacity alarm level threshold reached.
Note this alarm will be set as soon as the sensor
detect the high level.
Warning for Low
Returned Light In-
tensity
Returned light low. Run align function again and
make sure the beam is aligned with reflector.
Reduce distance to reflector if possible.
Alarm for Low Re-
turned Light In-
tensity
Returned light to low. Run align function again
and make sure the beam is aligned with reflector.
Reduce distance to reflector if possible.