Greenline 40
125
AC Error 2 listing (HEX field):
Error Name
HEX
Code
DEC
Code
AC response Reason Remedy Note
No error 0x0000 / / / /
Over current
0x0001 17 Power reduction Phase current above 150A Check load 1
Motor
overheat
0x0002 18 Power reduction
Measured motor temperature
above 115°C
Reduce load, el.
motor cooling
required
HCU
overheat
0x0004
19 Power reduction
HCU temperature
above 85°C
Reduce load, HCU
cooling required
High bat.
current
0x0008
20 Power reduction
Calculated battery current
above max level
Reduce load 2
High ph.
current
0x0010
21 Power reduction
Phase current
above max level
Reduce load 2
High elect.
power
0x0020
22 Power reduction
Calculated electrical power
above max level
Reduce load 2
High mech.
power
0x0040
23 Power reduction
Calculated mechanical power
above max level
Reduce load 2
/ 0x0080 24
Charging
level invalid
0x0100 25
Neutral mode /
Charging
interrupted
Battery voltage do not follow
charger predefined level
Wait for battery
voltage drop
Charging
voltage high
0x0200 26
Neutral mode /
Charging
interrupted
Battery voltage in
generator mode above 53,4 V
Wait for battery
voltage drop
Bat. volt.
prop. min
0x0400 27
Neutral mode /
El. prop. interrupted
Battery voltage in electric
propulsion mode below 42 V
Recharge battery
DC-link volt.
prop. min
0x0800 28
Neutral mode /
El. prop. interrupted
DC-link voltage in electric
propulsion mode below min
level
Recharge battery /
Reduce load
3
DC-link volt.
prop. max
0x1000 29
Neutral mode /
El. prop. interrupted
DC-link voltage in electric
propulsion mode above max
level
Wait for DC-link
voltage-drop
3