EasyManua.ls Logo

Groeneveld OnePlus - System De-aerating Procedure; System Commissioning

Groeneveld OnePlus
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Automatic Greasing System OnePlus
Installation
35
Date of issue: October 2011
EG1605R01
4.9 De-aerating of the greasing system
The greasing system can be de-aereted in three different ways:
Method 1
This method can be used when a pneumatic grease pump is available in the work-
shop. With such a pump the greasing system can be de-aereted quickly by connect-
ing the primary grease line of the OnePlus system (at the pump unit) with that
pneumatic pump. After the system has been de-aereted, the primary line must be
reconnected to the output port of the pump unit.
Method 2
This method may be used when only a hand-operated grease gun is available. The
procedure is the same as described for method 1.
Method 3
This method will have to be used when neither a pneumatic system or a hand-op-
erated grease gun is available. There is no need to disconnect the primary grease
line from the pump unit. The pump unit must then be started and be allowed to
run until all grease points shown a closed collar of fresh grease.
4.10 Commissioning of the greasing system
During commissioning, the system parameters (greasing interval, grease supply per
phase, etc.) must be set or checked using the UniGINA. Detailed information about
the system parameters and the operation of the UniGINA can be found in the User
Manual UniGina OnePlus.
After you have set or checked the system parameters with the UniGINA, you should
also enter the INPUT/OUTPUT menu and check:
the correct functionally of the control input, when activated.
the functionality of the pump (manual operation).
the functionality of the optional indicator lamp, when mounted (manual
operation).
the functionality of the optional distribution block monitoring switch, when
mounted (activate pump manually and watch the switch changes state within
reasonable time).
Perform a test cycle and check the correct functionality.

Table of Contents