8.4 Installation altitude
Installation altitude is the height above sea level of
the installation site.
Motors installed up to 1000 m above sea level can
be loaded 100 %.
The motors can be installed up to 3500 m above sea
level.
Fig. 12 Motor output power in relation to altitude
In order to maintain the galvanic isolation and ensure
correct clearance according to EN 60664-1:2007,
you must adapt the supply voltage to the altitude:
Fig. 13 Supply voltage for three-phase motor in
relation to altitude
Fig. 14 Supply voltage for single-phase motor in
relation to altitude
8.5 Humidity
Maximum humidity: 95 %.
If the humidity is constantly high and above 85 %,
one of the drain holes in the drive-end flange must
be open. See section 6.6 Drain holes.
8.6 Motor cooling
To ensure cooling of motor and electronics, observe
the following:
Position the motor in such a way that adequate
cooling is ensured. See section 6.4 Ensuring
motor cooling.
The temperature of the cooling air must not
exceed 50 °C.
Keep cooling fins and fan blades clean.
9. User interfaces
You can make the pump settings by means of the
following user interfaces:
Control panels
Standard control panel.
See section 10. Standard control panel.
Advanced control panel.
See section 11. Advanced control panel.
Remote controls
Grundfos GO.
See section 12. Grundfos GO.
If the power supply to the pump is switched off, the
settings are stored.
Motors installed more than 1000 m above
sea level must not be fully loaded due to
the low density and consequent low
cooling effect of the air.
TM05 5243 3717TM06 9866 3617TM06 9867 3617
0
500 1000 1500 2000 2500 3000 3500
Altitude [m]
P2 [%]
500
480
460
440
420
380
400
0 500 1000 2000 2500 3000 3500
4000
1500
Supply voltage [V]
Altitude [m]
0 500 1000 1500 2000 2500 3000 3500 4000
200
210
220
230
240
250
Supply voltage [V]
Altitude [m]
WARNING
Hot surface
Death or serious personal injury
- Only touch the buttons on the display as
the product may be very hot.
WARNING
Electric shock
Death or serious personal injury
- If the control panel is cracked or
perforated, replace it immediately.
Contact the nearest Grundfos sales
company.