English (GB)
45
13.22 "Service"
"Time until next service" (Motor bearing service)
This display shows when to replace the motor
bearings. The controller monitors the operating
pattern of the motor and calculates the period
between bearing replacements.
Displayable values:
• "in 2 years"
• "in 1 year"
• "in 6 months"
• "in 3 months"
• "in 1 month"
• "in 1 week"
•"Now"
"Bearing replacements"
Indicates the number of bearing replacements that
have been done during the lifetime of the motor.
Bearings replaced (Motor bearing maintenance)
When the bearing monitoring function is active, the
controller gives a warning when the motor bearings
are to be replaced.
When you have replaced the motor bearings, confirm
this action by pressing [Bearings replaced].
13.23 "Number" (Pump number)
You can allocate a unique number to the pump. This
makes it possible to distinguish between pumps in
connection with bus communication.
Factory setting
See section 30. Factory settings.
13.24 "Radio communication"
(Enable/disable radio comm.)
You can set the radio communication to either
enabled or disabled. You can use this function in
areas where radio communication is not allowed.
IR communication remains active.
Factory setting
See section 30. Factory settings.
13.25 Language
This menu is only available in the advanced control
panel.
In this menu you can select the desired language. A
number of languages is available.
13.26 "Date and time" (Set date and time)
You can set date and time as well as how they are to
be shown in the display:
• Select date format:
YYYY-MM-DD
DD-MM-YYYY
MM-DD-YYYY.
• Select time format:
HH:MM 24-hour clock
HH:MM am/pm 12-hour clock.
• Set date
•Set time.
Factory setting
See section 30. Factory settings.
Pump variant "Service"
TPE, TPED, NBE,
NBGE, NKE, NKGE
●
TPE, TPED, NBE, NKE
Series 2000
●
Pump variant "Number"
TPE, TPED, NBE,
NBGE, NKE, NKGE
●
TPE, TPED, NBE, NKE
Series 2000
●
Pump variant
"Radio
communication"
TPE, TPED, NBE,
NBGE, NKE, NKGE
●
TPE, TPED, NBE, NKE
Series 2000
●
Pump variant Language
TPE, TPED, NBE,
NBGE, NKE, NKGE
●
TPE, TPED, NBE, NKE
Series 2000
●
Pump variant "Date and time"
TPE, TPED, NBE,
NBGE, NKE, NKGE
●
TPE, TPED, NBE, NKE
Series 2000
●