30 Model 675 User Instructions
3. Add the sample pieces and press the [F1] Accept key to accept the sample.
4. Continue to add pieces to count
Without Auto Tare
1. If the sample size is known and a container is used:
1a. Place an empty container on the scale and press [TARE] key.
1b. Place the sample in the container.
1c. Key in the sample size and then press the [F1] Sample or [SAMPLE] key. The
scale will accept the current weights as a sample and will display the quantity.
-or-
2. If the sample size is known and no container is used:
2a. Place the sample on the scale.
2b. Key in the sample size and then press the [F1] Sample or [SAMPLE] key. The
scale will accept the current weights as a sample and will display the quantity.
Figure 3.1 Example: [5] [0] [SAMPLE]
Store Part Number
Part numbers can be stored in a database and can be recalled later with necessary
data such as the average piece weight and description. Make sure you enter a part
number before entering a Bin #, Lot # or APW.
1. Scan in a part number or key in the part number and press the [F3] (Rec/New)
key. The other data fields will be cleared.
1a. If you want to add a part description, Bin #, Lot # and/or an APW either scan it
in or press [F4] (Entry).
1b. If the field was scanned it will automatically be populated. Go to step 3.
1c. If none of these fields are desired, go to step 3.
2. Press the key associated with the desired field (see page 9 for details on alpha
entry). Key in the text and press [ENTER].
3. Press [F2] to store the part number, APW, Lot #, Bin # and description.